>>7
So far I got everything valueable from the first partition, then I'll go over to the next working one. Maybe chkdsk or testdisk can fix the broken one, since it could just be a broken MFT I have there.
Meanwhile some funny stuff from smartctl:
Running command: X:\Programs\smartmontools\smartctl.exe -a /dev/hda
--- Here is the output ---
smartctl version 5.33 [i386-pc-mingw32] Copyright (C) 2002-4 Bruce Allen
Home page is
http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: HDS722516VLAT80
Serial Number: VN643ECDD6XV6D
Firmware Version: V34OA6EA
User Capacity: 164,696,555,520 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 6
ATA Standard is: ATA/ATAPI-6 T13 1410D revision 3a
Local Time is: Fri Feb 08 14:12:56 2008 Local time
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (3585) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 60) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 089 089 060 Pre-fail Always - 1966127
2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0
3 Spin_Up_Time 0x0007 116 116 024 Pre-fail Always - 214 (Average 301)
4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 1465
5 Reallocated_Sector_Ct 0x0033 001 001 005 Pre-fail Always FAILING_NOW 1894
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
8 Seek_Time_Performance 0x0005 100 100 020 Pre-fail Offline - 0
9 Power_On_Hours 0x0012 098 098 000 Old_age Always - 17085
10 Spin_Retry_Count 0x0013 095 095 060 Pre-fail Always - 65536
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 1456
192 Power-Off_Retract_Count 0x0032 099 099 050 Old_age Always - 2033
193 Load_Cycle_Count 0x0012 099 099 050 Old_age Always - 2033
194 Temperature_Celsius 0x0002 161 161 000 Old_age Always - 34 (Lifetime Min/Max 14/53)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 3152
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 5
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 16